D5072S (1ch) D5072D (2ch)
DATA SHEET DOWNLOAD
| I.S. SIL2 Multifunction Temperature Converter
- SIL 2 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- mV, TC, 2/3/4wire res./RTD or potentiometer input
- Duplication/inversion/scaling/custom output
- Selectable CJC: int. PT1000, external RTD or fixed
- Burnout/internal/cjc/in sensor fault monitor
- Alarm output with user-settable trip points
- Modbus RTU RS-485 for monitor & configuration
- Fully programmable operating parameters
- High Accuracy, µP controlled A/D converter
- Three port isolation, Input/Output/Supply
- High Density, two channels per unit (D5072D)
- D5072D can configure as Duplicator
Duplicator

|  |
 |
D5072S-087(1ch) D5072D-087(2ch)
DATA SHEET DOWNLOAD
| I.S. SIL2 Resistance Repeater
- SIL 2 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- 2/3/4wire res./RTD or potentiometer input
- Burnout Fault detection
- Fully programmable operating parameters
- High Accuracy
- Three port isolation, Input/Output/Supply
- High Density, two channels (D5072D-087)
D5072D-087 can configure as Duplicator
Duplicator 
|  |

|
D5072S-096(1ch) D5072D-096(2ch)
DATA SHEET DOWNLOAD
| I.S. SIL2 Thermocouple/mV Repeater
- SIL 2 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- mV or thermocouple input
- Output duplication
- Fully programmable operating parameters
- High Accuracy, µP controlled A/D converter
- Three port isolation, Input/Output/Supply
- High Density, two channels per unit (D5072D-096)
Duplicator
 |  |
 |
D5072S-099(1ch) D5072D-099(2ch)
DATA SHEET DOWNLOAD
| I.S. SIL2 Sink-Out Temperature Converter
- SIL 2 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- mV, TC, 2/3/4wire res./RTD or potentiometer input
- Duplication/inversion/scaling/custom output
- Selectable CJC: int. PT1000, external RTD or fixed
- Burnout/internal/cjc/in sensor fault monitor
- Alarm output with user-settable trip points
- Modbus RTU RS-485 for monitor & configuration
- Fully programmable operating parameters
- High Accuracy, µP controlled A/D converter
- Three port isolation, Input/Output/Supply
- High Density, two channels per unit (D5072D-099)
Duplicator
|  |
 |
D5273S
DATA SHEET DOWNLOAD
| I.S. SIL2 Temperature Converter & Trip Amplifier
- SIL 2 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- mV, TC, 2/3/4wire res./RTD or potentiometer input
- Two independent Trip Amplifiers (SPDT relay contacts)
- Inversion/scaling/custom output
- Selectable CJC: internal PT1000, external RTD or fixed
- Burnout/internal/cjc/in sensor fault monitor
- Alarm output with user-settable trip points
- Modbus RTU RS-485 for monitor & configuration
- Fully programmable operating parameters
- High Accuracy, µP controlled A/D converter
- Three port isolation, Input/Output/Supply
|  |
D5274S
DATA SHEET DOWNLOAD
| I.S. SIL2 Temp. Trip Amplifier w/ Zero/Span Trimmer
- SIL 2 / SC 2 (pending)
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- mV, TC, 2/3/4wire res./RTD or potentiometer input
- Two independent Trip Amplifiers (SPDT relay contacts)
- Inversion/scaling/custom output
- Selectable CJC: internal PT1000, external RTD or fixed
- Burnout fault monitor
- Alarm output with user-settable trip points
- Zero/span output current trimmers
- Extended power supply for 12/24 Vdc nominal voltage
- Fully programmable operating parameters
- High Accuracy, µP controlled A/D converter
- Three port isolation, Input/Output/Supply
|  |
X1-IS-TMP-01
DATA SHEET DOWNLOAD
| I.S. SIL2 Temperature Converter
- SIL 2 / SC 3
- Input from Zone 0 / Division 1
- Installation in Zone 2 / Division 2
- Loop disconnection to ease maintenance operations
- Programmable fault in case of burnout or threshold exceeding
- mV, TC, 2/3/4-wire resistance/RTD or potentiometer input
- Inversion/scaling/custom output current
- Mechanical polarization key to prevent destructive mismatches
- Fully programmable through Gateway
- High Accuracy
- Three port isolation, Input/Output/Supply
 | 
 |