Rugged instrumentation for reliable measurement and control
Signal Isolators, Repeaters and Converters
Moore Industries Signal Isolators, Converters and Splitters protect your process by converting, isolating, splitting, boosting and stepping down process signals so field instruments can interface directly with indicators, recorders, DCS, PLC, Asset Management, Control and SCADA systems.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | HIX & HIT | 2- and 4-Wire HART® Isolators and Repeater | 4-20mA | 4-20mA | 12-42Vdc, Output Loop Powered | HART passthru | DATA SHEET |
![]() | SSX & SST | HART® Functional Safety Isolators, Repeaters and Splitters | 4-20mA | 4-20mA | 24Vdc, 117Vac, 230Vac, Output Loop Powered | HART passthru depend on the models SIL2 | DATA SHEET |
![]() | ECT-DIN | Signal Isolator, Converter, Repeater, Booster and Splitters | 4-20mA 10-50mA 1-5V 0-100V etc | 4-20mA | 12-42dc, Input Loop Powered, Output Loop Powered | DATA SHEET | |
![]() | SFY | Functional Safety Frequency-to-DC Transmitter with Display | Frequency | 4-20mA | 12-42dc, Input Loop Powered, Output Loop Powered | SIL2 | DATA SHEET |
![]() | SIY | PC-Programmable Signal Isolator/Repeater/Converter | Current Voltage | 4-20mA | 12-42dc, 10-30dc, Input Loop Powered, Output Loop Powered | DATA SHEET | |
![]() | SDY | SDY PC Programmable Signal Isolator, Repeater and Converter | Current Voltage | 4-20mA | 10-42dc, 10-30dc IS option | DATA SHEET | |
![]() | MIX & MIT | Multi-Channel Signal Isolator, Repeater and Converter | Current Voltage | 4-20mA | 12-42dc, MIT ; U : 20-125Vdc,or 90-250Vac | 2channel or 4 channel high density model | DATA SHEET |
![]() | SIX | 2-Wire Isolator/Repeater/Converter | Current Voltage | 4-20mA, 10-50mA | 10-42dc (Loop powered on output side) | -10 Vdc ~ +10 Vdc for Bailey | DATA SHEET |
![]() | FCT | Field-Configurable Signal Isolator, Converter and Repeater | 0-20mA , 4-20mA, 0-50mA, 10-50mA 0-5V , 1-5V, 0-10V | 0-20mA , 4-20mA 0-5V, 1-5V, 0-10V | 22- 300Vdc or 90- 260Vac, | DATA SHEET | |
![]() | FDY | PC-Programmable Frequency-to-DC Transmitter with Display | Frequency | 4-20mA | 10-42dc, 10-30dc IS option | 10-250Vac or 0.1-30Vdc amplitude | DATA SHEET |
Alarm Trips and Trip Amplifiers
Moore Industries Alarm Trips and Trip Amplifiers bring reliable and precise monitoring of critical process variables, ensuring safe and efficient operation in industrial applications. They provide on/off control, warn of trouble, or provide emergency shutdown with one or more programmable alarm (relay) outputs when a monitored process signal falls outside of a selected high and/or low limit.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | SLA | Functional Safety Multiloop Logic Solver and Alarm | 6 inputs ; mV, T/C, RTD, Ohm, Current, Voltage | 4 SPDT relays, 3 AO (option) RS485 Modbus (option) | 10-30 dc | SIL2/3 (SC) Logic Solver | DATA SHEET |
![]() | SPA2 | Programmable Limit Alarm Trip | mV, T/C, RTD, Ohm, Current, Voltage | 4 SPDT relays or 2 DPDT relays, 1 AO (option) | 21.6-375Vdc or 90-260Vac | DATA SHEET | |
![]() | STA | Functional Safety Limit Alarm Trip | mV, T/C, RTD, Ohm, Current, Voltage | 3 SPDT relays, 1 AO (option) | 21.6-375Vdc or 90-260Vac | SIL2/3 (SC) Safety Trip Alarms Dual process relays and one fault relay | DATA SHEET |
![]() | SRM | Functional Safety Relay Module | 1 Contact Closure | 3 NO 1 NC | 24dc | SIL2/3 (SC) Safety Relay | DATA SHEET |
![]() | NCS | NET Concentrator System with Multipoint Analog Alarm | 60 AI, Temp. inputs | 8 Relay | 24dc | 32 Alarms and 8 physical relays | DATA SHEET |
![]() | ECA | Current and Voltage Limit Alarm Trip | 4-20mA, 1-5V, 0-5A ac | 2 Relays | 24dc, 117ac, 230ac | DATA SHEET | |
![]() | 330R2 | 1/8 DIN Process and Temperature Panel Meter & Alarm | T/C, RTD, Current, Volt | 2 SPDT Relays 1 AO (option) | 12-24VAC or 12-36VDC (LO) 85-265VAC or 90-265VDC (HI) | Process and Temperature Meter | DATA SHEET |
![]() | HIM | Smart HART® Loop Interface and Monitor | HART | 2AO, 3AO, MB, MB1AO, | 24dc | 1 DPDT relay (option) or 2 SPDT relays (option) | DATA SHEET |
![]() | DDA | Current and Voltage Limit Alarm Trip | 0-20mA, 1-5mA, 4-20mA, 10-50mA, 0-1V, 0-5V, 1-5V, 0-10V | 1 DPDT relay or 2 SPDT relays | 24dc | 1 AO (option) | DATA SHEET |
![]() | ALX | ALX 2-Wire Direct Current Alarm | 4-20mA, 10-50mA | 1 SPST (CC) relay | Loop Power | DATA SHEET |
I/P and P/I Converters
Convert a current signal to a pneumatic signal so a DCS, PLC, or host system can control a valve or actuator; or convert pneumatic signals to current signals so remote pneumatic devices can interface with control and monitoring systems.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | IPT2 | IPT2 Current-to-Pressure (I/P) Transmitter | 4-20mA, 4-12mA, 12-20mA | 0.2 - 1Bar | 1.4 Bar (Supply Pressure) | DATA SHEET | |
![]() | IPH2 & IPX2 | Type 4X & Explosion-Proof/Flameproof Current-to-Pressure (I/P) Transmitters | 4-20mA, 4-12mA, 12-20mA | 0.2 - 1Bar | 1.4 Bar (Supply Pressure) | IPH2 : NEMA4X IPX2 : Explosion Proof | DATA SHEET |
![]() | PIT | Pressure-to-Current Transmitters (2 wire DIN Housing) | 0-5PSIG, 0-7PSIG, 0-10PSIG, 0-15PSIG, 0-27PSIG 0-30PSIG, 0-60PSIG, 0-100PSIG, 3-15PSIG, 3-27PSIG, 5-25PSIG 6-30PSIG 10-50PSIG 0.2-1BAR, 0.4-2BAR, 0-6BAR, 20-100KPA, 20-186KPA, 0-500KPA 0.02- 0.10MPA, 0.2-1KGCM2, 0-30INHG | 4-20mA | 12-24DC, 12-30DC, 12-42DC | special ranges available, consult factory for specification changes | DATA SHEET |
| PIX | 2-wire, Hockey Puck Housing | 3-15PSIG,3-27PSIG , 0.2-1BAR, 0.2-1KGCM2, 20-100KPA | 4-20mA | 12-24DC, 12-42DC | |||
| PIF | 2-wire, Thermoplastic Housing | 12-42DC | |||||
| PIT | 4-wire, Standard Housing | 117AC, 220AC, 240AC | |||||
![]() | PIH | Field-Mount Pressure-to-Current Transmitter | 0-15PSIG 3-15PSIG 0-30PSIG 3-27PSIG 6-30PSIG 0.2-1BAR 0.2-1KGCM2 20-100KPA 20-186KPA | 4-20mA | 12-42DC | DATA SHEET |
HART Gateways, Monitors and Interfaces
Moore Industries HART gateways and loop monitors reduce wiring costs, help prevent costly shutdowns, warn of unwanted process conditions and provide early indication of device faults.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | HES | HART® to Ethernet Gateway System | HART | Ethernet | 9-30dc | 1ch HART, 4ch HART | DATA SHEET |
![]() | HCS | HART® Concentrator System HART-to-MODBUS RTU Converter | HART | MB485 MB232 | 9-30dc | Modbus RTU | DATA SHEET |
![]() | HIM | Smart HART® Loop Interface and Monitor | HART | 2AO, 3AO, MB, MB1AO, | 24dc | 1 DPDT relay (option) or 2 SPDT relays (option) | DATA SHEET |
Functional Safety Solutions
Moore Industries Functional Safety Solutions provide reliable and SIL-certified instrumentation designed to enhance safety and compliance in critical process applications. The SIL 2 and SIL 3 capable FS Functional Safety Series instruments are third-party certified by exida to IEC 61508 standards designed and built for use in Safety Instrument Systems.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | SLA | Functional Safety Multiloop Logic Solver and Alarm | 6 inputs ; mV, T/C, RTD, Ohm, Current, Voltage | 4 SPDT relays, 3 AO (option) RS485 Modbus (option) | 10-30 dc | SIL2/3 (SC) Logic Solver | DATA SHEET |
![]() | STA | Functional Safety Limit Alarm Trip | mV, T/C, RTD, Ohm, Current, Voltage | 3 SPDT relays, 1 AO (option) | 21.6-375Vdc or 90-260Vac | SIL2/3 (SC) Safety Trip Alarms Dual process relays and one fault relay | DATA SHEET |
![]() | SSX & SST | HART® Functional Safety Isolators, Repeaters and Splitters | 4-20mA | 4-20mA | 24Vdc, 117Vac, 230Vac, Output Loop Powered | HART passthru depend on the models SIL2 | DATA SHEET |
![]() | SRM | Functional Safety Relay Module | 1 Contact Closure | 3 NO 1 NC | 24dc | SIL2/3 (SC) Safety Relay | DATA SHEET |
![]() | STZ | Functional Safety Dual Input Smart HART® Temperature Transmitters | T/C, RTD, 0-4,000 Ohm, -50 - 1,000 mV | 4-20mA | 12-42dc 10-30dc (IS option) | SIL2/3 (SC) | DATA SHEET |
![]() | SFY | Functional Safety Frequency-to-DC Transmitter with Display | Frequency | 4-20mA | 12-42dc, Input Loop Powered, Output Loop Powered | SIL2 | DATA SHEET |
![]() | SLD | Functional Safety Programmable Loop Display | 4-20mA | Display | Loop Powered (2.3VLP) | SIL3 | DATA SHEET |
Temperature Transmitters
Moore Industries Temperature Transmitters are high-performance instruments designed to provide accurate, reliable, and scalable temperature measurement solutions for industrial applications. The Universal PC-Programmable, Smart HART® Temperature Transmitters convert and send RTD or thermocouple signals ready for direct interface with an indicator, recorder, PLC, DCS, or SCADA system.
![]() | TDZ3 | Dual Input HART Temperature Transmitters With Display | T/C, RTD, 0-4,000 Ohm, -50 - 1,000 mV | 4-20mA | 10-42dc, 10-30dc IS option | DATA SHEET | |
![]() | STZ | Functional Safety Dual Input Smart HART® Temperature Transmitters | T/C, RTD, 0-4,000 Ohm, -50 - 1,000 mV | 4-20mA | 10-42dc, 10-30dc IS option | SIL2 (SC) | DATA SHEET |
![]() | THZ3 | Dual Input HART Temperature Transmitters | T/C, RTD, 0-4,000 Ohm, -50 - 1,000 mV | 4-20mA | 10-42dc | DATA SHEET | |
![]() | TRY, TRX & TDY | PC Programmable Temperature Transmitters With and Without Display | T/C, RTD, 0-4,000 Ohm, -50 - 1,000 mV | 4-20mA | 10-42dc, 10-30dc IS option | TRY : Isolated TRX : Non-Isolated TDY : with display | DATA SHEET |
![]() | HTZ | Smart HART Humidity and Temperature Transmitter With Display | HSM | HDM | HDM | HTZ : 1 HSM + 1 HDM | DATA SHEET |
![]() | RIY | Programmable Isolated RTD Transmitter | RTD | 4-20mA | 10-42dc, 10-30dc IS option | Refer to RTD table on the D/S | DATA SHEET |
| TIY | Programmable Isolated T/C Transmitter | T/C | 4-20mA | 10-42dc, 10-30dc IS option | Refer to T/C table on the D/S | DATA SHEET | |
| SPT | Programmable Isolated Temperature Transmitter | mV, ohm, T/C, RTD | 4-20mA, 1-5Vdc | 24Vdc U: 22-300Vdc or 90-260Vac | 1 SPDT (form C) relay option | DATA SHEET | |
![]() | TMZ | MODBUS Temperature Transmitters and Signal Converters | T/C, RTD, mV, Ohm, Current, Voltage | Modbus RTU (RS485) | 24dc | HLPRG : Current, Voltage TPRG : mV, T/C, Ohm, RTD 2 PRG : Dual Inputs | DATA SHEET |
![]() | T2X | Non-Isolated PC-Programmable RTD Transmitters | RTD, 0-2,000Ohm | 4-20mA | 8-42dc, 8-30dc IS option | DATA SHEET |
Remote I/O and RTUs
Remote I/O and RTUs eliminate expensive T/C and RTD extension wire and other point-to-point wires by sending temperature measurements, process monitoring and control signals between the field and control room on one digital communication link.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | NCS | NCS NET Concentrator System® Process Control and Distributed I/O | T/C, RTD, Ohm, contact, Current, Voltage | AO, DO, Modbus, Ethernet | 20-30dc | DATA SHEET | |
![]() | TCS | Temperature Concentrator System™ Multi-Channel Transmitter | RTD, T/C, 0-4,000ohms, -50 to +1000mV | HART | 15-42DC, 15-30DC (IS option) | Temperature Multiplexer System | DATA SHEET |
![]() | HCS | HART® Concentrator System HART-to-MODBUS RTU Converter | HART | MB485, MB232 | 9-30DC | Modbus RTU | DATA SHEET |
![]() | HES | HART® to Ethernet Gateway System | HART | Ethernet | 9-30dc | 1ch HART, 4ch HART | DATA SHEET |
![]() | TCM | 16 Channel Temperature Concentrator Module - Used with HMC and HES | RTD, T/C, 0-4,000ohms, -50 to +1000mV | HART | 15-42DC, 15-30DC (IS option) | Temperature Multiplexer | DATA SHEET |
![]() | TMZ | MODBUS RTU Single and Dual Channel I/O Modules | T/C, RTD, mV, Ohm, Current, Voltage | Modbus RTU (RS485) | 24dc | HLPRG : Current, Voltage TPRG : mV, T/C, Ohm, RTD 2 PRG : Dual Inputs | DATA SHEET |
![]() | HMC | HART-to-MODBUS RTU Converter - Used with TCM | HART | Modbus RTU (RS485) | 24dc (20-30dc) | DATA SHEET | |
![]() | CPMS | Cathodic Protection Monitoring System | 4 rangeable cathodic protection monitoring channels with 4 discrete (contact closure) input channels | Dual MODBUS RTU (RS-485), One Ethernet (MODBUS/TCP) | 20-30 dc, 90-260 Vac | DATA SHEET | |
![]() | CCS | Cable System Peer-to-Peer I/O System | 16ch AI, DI | MB485 16ch AO, DO | 18-30 dc | DATA SHEET |
Indicators and Displays
Moore Industries Indicators and Displays take a process input signal from a temperature, pressure, level, or flow transmitter loop and provide real-time process status in rugged and hazardous field environments.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | PSD | PC-Programmable Loop Display | 4-20mA | Programmable any EGU | 2.3VLP Loop Powered | DATA SHEET | |
![]() | SLD | Functional Safety PC-Programmable Loop Display | 4-20mA | Programmable any EGU | Bus Powered | SIL3 (It is not SIL3 assessed to be used as part of the safety function.) | DATA SHEET |
![]() | 330R2 | 330R2 1/8 DIN Process and Temperature Panel Meter & Alarm | 0-20mA, 4-20mA, ±20mA, 0-5V, 1-5V, 0-10V, ±10V, TC & RTD | 2 Alarm Outputs, Analog Output | HI : 85-265VAC or 90-265VDC LO: 12-24VAC or 12-36VDC | DATA SHEET | |
![]() | SPD | PC-Programmable Field-Mount Loop Display (Type 4X, IP66) | 4-20mA | Programmable any EGUr | 2.3VLP Loop Powered | TYPE 4X, IP66 | DATA SHEET |
Fieldbus Device Couplers and Power Supplies
Find a fieldbus power supply or device coupler that will power, protect and terminate multiple fieldbus devices on FOUNDATION Fieldbus™ and PROFIBUS PA segments.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | TRUNKGUARD TG200 | TG200 Series Device Coupler | Fieldbus or PROFIBUS PA connection | Fieldbus or PROFIBUS PA connection | Bus Powered | 4 spur, 8 spur, 10 spur, 12 spur and 20 spur | DATA SHEET |
![]() | TRUNKGUARD TG300 | TG300 Series Device Coupler | Fieldbus or PROFIBUS PA connection | Fieldbus or PROFIBUS PA connection | Bus Powered | Zone 1, Zone 2 4 spur, 8 spur | DATA SHEET |
![]() | TRUNKGUARD TPS400 | TPS400 Fieldbus Power Supply | 24Vdc | Redundant DC Segment Power | 24Vdc | General Purpose and Non - Incendive application | DATA SHEET |
![]() | TRUNKSAFE TS200 | TS200 Fault-Tolerant Series Device Coupler | 24DC | DC Segment Power | 24Vdc | REDUNDANT TRUNK Yokogawa, DeltaV, Schneider/Invensys, PROFIBUS PA HOST, Other | DATA SHEET |
![]() | ROUTE-MASTER RM100 | ROUTE-MASTER Fieldbus System | 115Vac / 230Vac | Redundant DC Segment Power (350mA I.S.) | 15Vac / 230Vac | Redundant IS Power supply Entity & FISCO (1900m) Zone1, Zone2 | DATA SHEET |
PID Controllers and Backup Stations
Precisely control and monitor a temperature, pressure, level or flow process variable in batch and continuous processes, or back up critical or safety-related loops controlled by PLC, DCS and other control systems with our PID controllers and backup stations.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | 535 | 1/4 DIN Process Controller | Dual inputs : T/C, RTD, mV, Current, Voltage | 4 outputs RS485 | 24Vdc/ac, 90-250Vac | Single Loop PID Controller, PowerTune, NEMA4X | DATA SHEET |
![]() | 545 | 1/4 DIN Dual Loop Process Controller | Dual inputs : T/C, RTD, mV, Current, Voltage | 4 outputs RS485 | 90-250Vac, 24Vac (option) | Dual Loop PID Controller, Cascade Control Ratio Control, Feed Forward , PowerTune, NEMA4X | DATA SHEET |
![]() | 532 | 1/4 DIN Auto/Manual Station | T/C, RTD, mV, Current, Voltage (PV, CV) | CV Analog Output & 3 Relays RS485 | 90-250Vac, 24Vdc/ac (option) | PID Backup Station Remote Setpoint (option) 3 digital inputs (option) | DATA SHEET |
![]() | 531 | 1/4 DIN DCS/PLC Control Backup Station | Programmable PV, CV from Primary Control Loop | CV Analog Output & 3 Relays RS485 | 90-250Vac, 24Vdc/ac (option) | HOT PID Backup Station Auto / Manual Station | DATA SHEET |
![]() | 555 | 1/4 DIN Chlorination/ Dechlorination Controller | Dual inputs : mV, Current, Voltage | 2 Analog Outputs, 2 Relays | 90-250Vac, 24Vdc/ac (option) | Flow Pacing Control Residual Chlorine Control Compound Loop Chlorine Control Dechlorination Control | DATA SHEET |
AC Power Transducers
Use these power transducers to schedule maintenance, identify inefficiencies, cut energy use, and prevent expensive damage to a load device like a motor, pump, heater, or mixer by accurately monitoring AC power use and trends.
MODEL | DESCRIPTION | INPUT | OUTPUT | POWER | FEATURE | ||
|---|---|---|---|---|---|---|---|
![]() | PWT, PWV & PVT | AC Power Transducers | 69 ac - 600 ac , 0 - 25A | -1 ~ 1mA, -10 ~ 10mA, 4-20mA, 4-20mAB, 1-5V | PWT : Watt Transducer PVT : VAR Transducer PWV : Watt, VAR Transducer | DATA SHEET | |
![]() | PAC | AC Current Transducers | 1A, 2A, 5A, 10A, 25A | 0-1mA 0-20mA (5A only) | Self Power | DATA SHEET | |
| 4-20mA, 1-5V | Auxiliary Power | ||||||
| PAV | AC Voltage Transducers | 0-90AC, 0-150AC, 0-300AC, 0-600AC | 0-1mA | Self Power | |||
| 90-150AC, 100-140AC, 110-130AC, 180-300AC, 200-280AC, 220-260AC | 0-1mA, 4-20mA, 1-5V | ||||||
| 0-90AC, 0-150AC, 0-300AC, 0-600AC | 4-20mA, 1-5V | Auxiliary Power | |||||
![]() | FDY | PC-Programmable Frequency-to-DC Transmitter with Display | PRG : 0.02-30Vac, 0.1-30Vdc 10-250Vac | 4-20mA | 10-42dc, 10-30dc IS option | FMEDA (option) | DATA SHEET |
![]() | PPA | Phase Angle Transducer | 0-69AC, 0-120AC, 0-240AC, 0-460AC, 0-600AC 1A, 2A, 5A, 10A, 25A 2x0-69AC, 2x0-120AC, 2x0-240AC, 2x0-460AC, 2x0-600AC | 4-20mA, 4-20mAB, 4-20mALEAD, -1~1mA, 0-1mAB | Angle Factor Phase Angle : 30, 45, 60, 90, 180 Power Factor : 0, 0.3, 0.5, 0.7 | DATA SHEET |